Features
● Magnetic induction (F), measuring the thickness of non-magnetic materials (e.g. Paint, plastic, porcelain enamel, copper, zinc, aluminum, chrome etc.) on magnetic materials (e.g. iron, nickel etc.). Zero point calibration and two-point calibration to correct the system error of the probe
● Features two working modes: DIRECT and BATCH & two measuring ways: CONTINUE and SINGLE
● Statistics include the mean, maximum, minimum, test numbers and standard deviation.
● Memory of 500 data
● Deletion of current data, calibrated data, limit data and all data stored.
● Integrated with printer to print the statists values if needed
● Low battery indication and error alarm
● Buzz during operation for indication
● Backlight for the screen
● Auto or manual shutdown
| Standard Delivery | Optional Accessory | ||
| Main unit | 1 | LA230 Printer | |
| Calibration foil set | 1 | ||
| Substrate | 1 | ||
| AAA1.5V battery | 2 | ||
| LANCE certificate | 1 | ||
| Warranty card | 1 | ||
| Instruction manual | 1 |
|
Probe Types |
F |
||
|
Measuring methods |
Magnetic induction |
||
|
Measuring range |
0~1250μm |
||
|
Display resolution |
0.1μm |
||
|
Tolerance |
Zero point calibration (μm) |
±(3%H+1) |
|
|
Two points calibration(μm) |
±[(1%~3%)H+1] |
||
|
Measuring condition |
Min.curvature radius(mm) |
convexity 1.5 |
concave 9 |
|
Min.testing area diameter(mm) |
Ø7 |
||
|
Critical thickness of substrate (mm) |
0.5 |
||
|
Power |
AAA 1.5V Battery (2 pcs) |
||
|
Working temperature |
0~40℃ |
||
|
Dimensions (mm) |
145×60×28 |
||
|
Weight (g) |
132 |
||